Hydrodynamic response time of magnetorheological fluid in valve mode: model and experimental verification

KUBÍK, M. ŠEBESTA, K. STRECKER, Z. JENIŠ, F. GOLDASZ, J. MAZŮREK, I.

English title

Hydrodynamic response time of magnetorheological fluid in valve mode: model and experimental verification

Type

journal article in Web of Science

Language

en

Original abstract

The transient behaviour of magnetorheological (MR) actuators affects their performance in progressive semiactive control suspension systems. The two sources of the time delay between the control signal and damping force are (i) dynamics of MR damper hardware and (ii) the MR fluid dynamics. The significant part of the MR fluid response time is the so-called hydrodynamic response time which is connected with the transient flow. Due to the above, the main aim of this paper is to experimentally determine the hydrodynamic response time of MR fluid and present systematic means for characterizing it via computational fluid dynamics (CFD) or analytical tools. The unique measurement method using an in-house patented slit flow rheometer is presented. The essence of the method relies on determining the pressure drop variation with the time spent by the fluid in the MR gap. The experimental determined hydrodynamic response time of MR fluid ranges from 0.4 ms to 1 ms for a selected gap size and a range of magnetic field stimuli. The results show that the higher the magnetic field, the lower the hydrodynamic response time is. Both CFD and analytical models exhibit similar trends as the experimental data. Moreover, the impact of temperature and gap size was determined. Here, the higher the gap size and temperature of MR fluid, the longer the response time is.

English abstract

The transient behaviour of magnetorheological (MR) actuators affects their performance in progressive semiactive control suspension systems. The two sources of the time delay between the control signal and damping force are (i) dynamics of MR damper hardware and (ii) the MR fluid dynamics. The significant part of the MR fluid response time is the so-called hydrodynamic response time which is connected with the transient flow. Due to the above, the main aim of this paper is to experimentally determine the hydrodynamic response time of MR fluid and present systematic means for characterizing it via computational fluid dynamics (CFD) or analytical tools. The unique measurement method using an in-house patented slit flow rheometer is presented. The essence of the method relies on determining the pressure drop variation with the time spent by the fluid in the MR gap. The experimental determined hydrodynamic response time of MR fluid ranges from 0.4 ms to 1 ms for a selected gap size and a range of magnetic field stimuli. The results show that the higher the magnetic field, the lower the hydrodynamic response time is. Both CFD and analytical models exhibit similar trends as the experimental data. Moreover, the impact of temperature and gap size was determined. Here, the higher the gap size and temperature of MR fluid, the longer the response time is.

Keywords in English

transient rheology; unsteady flow; hydrodynamic response time; response time; time constant; MR fluid, MR damper; magnetorheological fluid

Released

11.11.2021

ISSN

0964-1726

Volume

30

Number

12

Pages from–to

1–13

Pages count

13

BIBTEX


@article{BUT173006,
  author="Michal {Kubík} and Karel {Šebesta} and Zbyněk {Strecker} and Filip {Jeniš} and Janusz {Goldasz} and Ivan {Mazůrek} and Goldasz {Janusz},
  title="Hydrodynamic response time of magnetorheological fluid in valve mode: model and experimental verification",
  year="2021",
  volume="30",
  number="12",
  month="November",
  pages="1--13",
  issn="0964-1726"
}