Publication detail

Experimental and Computational Modelling of Aerosol Transport Using the BUT Benchmark Human Lung Model

LÍZAL, F. ELCNER, J. BĚLKA, M. JEDELSKÝ, J. JÍCHA, M.

English title

Experimental and Computational Modelling of Aerosol Transport Using the BUT Benchmark Human Lung Model

Type

journal article - other

Language

en

Original abstract

The aerosol team at the Brno University of Technology (BUT) has continuously developed a realistic human lung model and has used it for aerosol transport studies since 2006. The model was originally based on the digital reference model of [1] and contained airways from the throat down to the 7th generation of branching. It was gradually extended on the upper part with the mouth and nasal cavity. Also, its simplified versions were designed for specific research applications (Y-shaped model, semirealistic model). It was fabricated in two forms, as a transparent model for optical flow measurements and segmented for deposition testing. Originally it was ventilated using a single-cylinder breathing simulator that was later updated to a 5-piston breath generator which enables prescription of the individual course of breath for each lung lobe. The paper summarises up to date results acquired with different versions of the BUT model and gives examples of the outcomes acquired by several teams throughout Europe, including the COST Siminhale collaborators. Selected flow and deposition results were published in the Ercoftac database.

English abstract

The aerosol team at the Brno University of Technology (BUT) has continuously developed a realistic human lung model and has used it for aerosol transport studies since 2006. The model was originally based on the digital reference model of [1] and contained airways from the throat down to the 7th generation of branching. It was gradually extended on the upper part with the mouth and nasal cavity. Also, its simplified versions were designed for specific research applications (Y-shaped model, semirealistic model). It was fabricated in two forms, as a transparent model for optical flow measurements and segmented for deposition testing. Originally it was ventilated using a single-cylinder breathing simulator that was later updated to a 5-piston breath generator which enables prescription of the individual course of breath for each lung lobe. The paper summarises up to date results acquired with different versions of the BUT model and gives examples of the outcomes acquired by several teams throughout Europe, including the COST Siminhale collaborators. Selected flow and deposition results were published in the Ercoftac database.

Keywords in English

Aerosol, Human Lung, Benchmark, Experiment, CFD

Released

01.09.2021

Publisher

ERCOFTAC Bulletin

Location

Polsko, Czestochova

ISSN

2518-0991

Volume

128

Number

1

Pages from–to

36–43

Pages count

8

BIBTEX


@article{BUT177512,
  author="František {Lízal} and Jakub {Elcner} and Miloslav {Bělka} and Jan {Jedelský} and Miroslav {Jícha},
  title="Experimental and Computational Modelling of Aerosol Transport Using the BUT Benchmark Human Lung Model",
  year="2021",
  volume="128",
  number="1",
  month="September",
  pages="36--43",
  publisher="ERCOFTAC Bulletin",
  address="Polsko, Czestochova",
  issn="2518-0991"
}