Publication detail
On the Replacement of Articular Cartilage: The Friction of PVA Hydrogel Layer in Hip Simulator Test
NEČAS, D. YARIMITSU, S. REBENDA, D. SHINMORI, H. VRBKA, M. SAWAE, Y. MURAKAMI, T. KŘUPKA, I.
Czech title
Náhrada kloubní chrupavky: Tření vrstvy PVA hydrogelu v kyčelním simulátoru
English title
On the Replacement of Articular Cartilage: The Friction of PVA Hydrogel Layer in Hip Simulator Test
Type
journal article in Web of Science
Language
en
Original abstract
The present study focuses on friction evaluation of the polyvinyl alcohol (PVA) hydrogel layer, an anticipative material for cartilage replacement. The experiments were carried out in a ball-in-socket configuration using a pendulum hip simulator. The friction coefficients of ceramic-on-hydrogel pairs were compared with those of commercial implants (metal/ceramic heads vs UHMWPE, HXPE and metal/ceramic sockets). The effects of hydrogel ageing and hydration were studied, among others. The use of PVA inserts caused up to 98% reduction in friction coefficient compared to original hip pairs. The application of PVA for local or even complete cartilage replacement seems to be an outstanding opportunity in implantology.
Czech abstract
Tento článek se zabývá studiem tření vrstvy PVA hydrogelu, který je jedním z materiálu potenciálně vhodných pro náhradu chrupavky. Experimenty byly provedeny ve skutečné konfiguraci kulička-jamka s využitím kyčelního simulátoru na principu kyvadla. Součinitele tření párů keramické hlavice a PVA hydrogelových jamek byly porovnány s hodnotami pro komerční kloubní páry (kovová či keramická hlavice oproti UHMWPE, HXPE, keramické a kovové jamce). Kromě jiného byl rovněž analyzován vliv stárnutí hydrogelu. Využití vrstvy PVA vedlo k až 98% snížení součinitele tření v porovnání s originálními kyčelními páry. Aplikace PVA pro lokální či úplnou náhradu kloubní chrupavky tak představuje v oblasti implantologie výjimečnou příležitost.
English abstract
The present study focuses on friction evaluation of the polyvinyl alcohol (PVA) hydrogel layer, an anticipative material for cartilage replacement. The experiments were carried out in a ball-in-socket configuration using a pendulum hip simulator. The friction coefficients of ceramic-on-hydrogel pairs were compared with those of commercial implants (metal/ceramic heads vs UHMWPE, HXPE and metal/ceramic sockets). The effects of hydrogel ageing and hydration were studied, among others. The use of PVA inserts caused up to 98% reduction in friction coefficient compared to original hip pairs. The application of PVA for local or even complete cartilage replacement seems to be an outstanding opportunity in implantology.
Keywords in Czech
Náhrada chrupavky; Kyvadlový simulátor; Hydrogel; Tření
Keywords in English
Cartilage replacement; Pendulum simulator; Hydrogel; Friction
Released
01.02.2023
Publisher
Elsevier
Location
Nizozemsko
ISSN
0301-679X
Volume
178
Number
Part B
Pages from–to
108100–108100
Pages count
10
BIBTEX
@article{BUT180015,
author="David {Nečas} and David {Rebenda} and Martin {Vrbka} and Ivan {Křupka},
title="On the Replacement of Articular Cartilage: The Friction of PVA Hydrogel Layer in Hip Simulator Test",
year="2023",
volume="178",
number="Part B",
month="February",
pages="108100--108100",
publisher="Elsevier",
address="Nizozemsko",
issn="0301-679X"
}