Publication detail

Correlation of Acoustic and Optical Emission Signals Produced at 1064 and 532 nm Laser-induced Breakdown Spectroscopy (LIBS) of Glazed Wall Tiles

HRDLIČKA, A. -ZAORÁLKOVÁ, L. -GALIOVÁ, M. -ČTVRTNÍČKOVÁ, T. -KANICKÝ, V. -OTRUBA, V. -NOVOTNÝ, K. -KRÁSENSKÝ, P. -KAISER, J. -MALINA, R. -PÁLENÍKOVÁ, K.

Czech title

Korelace akustických a optických signálů při 1064 nm a 532 nm laserové ablace glazovaných dláždic

English title

Correlation of Acoustic and Optical Emission Signals Produced at 1064 and 532 nm Laser-induced Breakdown Spectroscopy (LIBS) of Glazed Wall Tiles

Type

journal article - other

Language

en

Original abstract

An acoustic signal was used for the internal standardization of laser-induced breakdown spectroscopy (LIBS) of a glazed wall tile. For the LIBS analyses, 1064 nm and 532 nm wavelengths of the Nd:YAG laser were utilized. The tile was depth profiled by a single-spot ablation from the glaze into the substrate. Some lines of major elements Si(I) 252.418, Si(I) 252.851, Al(I) 257.509, Cr(I) 295.368, Al(I) 309.271 nm and Ti(II) 334.904 nm were monitored. The decrease in the optical emissions during the ablation was successfully compensated for by normalization to the square power of the acoustic signal in the interval of 290-340 nm. This approach failed for the lines between 250-270 nm. The results were the same for both lasing wavelengths despite different irradiances. The acquired profiles are in good agreement with the reference X-ray fluorescence measurement.

Czech abstract

Článek pojednává o korelaci akustických a optických signálů při 1064 nm a 532 nm laserové ablace glazovaných dláždic

English abstract

An acoustic signal was used for the internal standardization of laser-induced breakdown spectroscopy (LIBS) of a glazed wall tile. For the LIBS analyses, 1064 nm and 532 nm wavelengths of the Nd:YAG laser were utilized. The tile was depth profiled by a single-spot ablation from the glaze into the substrate. Some lines of major elements Si(I) 252.418, Si(I) 252.851, Al(I) 257.509, Cr(I) 295.368, Al(I) 309.271 nm and Ti(II) 334.904 nm were monitored. The decrease in the optical emissions during the ablation was successfully compensated for by normalization to the square power of the acoustic signal in the interval of 290-340 nm. This approach failed for the lines between 250-270 nm. The results were the same for both lasing wavelengths despite different irradiances. The acquired profiles are in good agreement with the reference X-ray fluorescence measurement.

Keywords in English

LIBS, Acoustic signal, Normalization, Internal standard, Ceramic tile, Depth profiling

RIV year

2008

Released

24.10.2008

ISSN

0584-8547

Journal

Spectrochimica Acta Part B

Volume

64

Number

1

Pages from–to

74–78

Pages count

5

BIBTEX


@article{BUT48350,
  author="Jozef {Kaiser} and Radomír {Malina} and Kateřina {Brillová},
  title="Correlation of Acoustic and Optical Emission Signals Produced at 1064 and 532 nm Laser-induced Breakdown Spectroscopy (LIBS) of Glazed Wall Tiles",
  journal="Spectrochimica Acta Part B",
  year="2008",
  volume="64",
  number="1",
  month="October",
  pages="74--78",
  issn="0584-8547"
}