Originální abstrakt
An acoustic signal was used for the internal standardization of laser-induced breakdown spectroscopy (LIBS) of a glazed wall tile. For the LIBS analyses, 1064 nm and 532 nm wavelengths of the Nd:YAG laser were utilized. The tile was depth profiled by a single-spot ablation from the glaze into the substrate. Some lines of major elements Si(I) 252.418, Si(I) 252.851, Al(I) 257.509, Cr(I) 295.368, Al(I) 309.271 nm and Ti(II) 334.904 nm were monitored. The decrease in the optical emissions during the ablation was successfully compensated for by normalization to the square power of the acoustic signal in the interval of 290-340 nm. This approach failed for the lines between 250-270 nm. The results were the same for both lasing wavelengths despite different irradiances. The acquired profiles are in good agreement with the reference X-ray fluorescence measurement.
Český abstrakt
Článek pojednává o korelaci akustických a optických signálů při 1064 nm a 532 nm laserové ablace glazovaných dláždic
Anglický abstrakt
An acoustic signal was used for the internal standardization of laser-induced breakdown spectroscopy (LIBS) of a glazed wall tile. For the LIBS analyses, 1064 nm and 532 nm wavelengths of the Nd:YAG laser were utilized. The tile was depth profiled by a single-spot ablation from the glaze into the substrate. Some lines of major elements Si(I) 252.418, Si(I) 252.851, Al(I) 257.509, Cr(I) 295.368, Al(I) 309.271 nm and Ti(II) 334.904 nm were monitored. The decrease in the optical emissions during the ablation was successfully compensated for by normalization to the square power of the acoustic signal in the interval of 290-340 nm. This approach failed for the lines between 250-270 nm. The results were the same for both lasing wavelengths despite different irradiances. The acquired profiles are in good agreement with the reference X-ray fluorescence measurement.
Klíčová slova anglicky
LIBS, Acoustic signal, Normalization, Internal standard, Ceramic tile, Depth profiling
Rok RIV
2008
Vydáno
24.10.2008
ISSN
0584-8547
Časopis
Spectrochimica Acta Part B
Ročník
64
Číslo
1
Strany od–do
74–78
Počet stran
5
BIBTEX
@article{BUT48350,
author="Jozef {Kaiser} and Radomír {Malina} and Kateřina {Brillová},
title="Correlation of Acoustic and Optical Emission Signals Produced at 1064 and 532 nm Laser-induced Breakdown Spectroscopy (LIBS) of Glazed Wall Tiles",
journal="Spectrochimica Acta Part B",
year="2008",
volume="64",
number="1",
month="October",
pages="74--78",
issn="0584-8547"
}