Publication detail
Detection of lead in Zea mays by dual-energy X-ray microtomography at the SYRMEP beamline of the ELETTRA synchrotron and by atomic absorption spectroscopy
REALE, L. -KAISER, J. -PACE, L. -LAI, A. -FLORA, F. -BRUNO, A. -TUCCI, A. -ZUPPELLA, P. -MANCINI, L. -TROMBA, G. -RUGGIERI, F. -FANELLI, M. -MALINA, R. -LIŠKA, M. -POMA, A.
Czech title
Detekce rozložení olova v různých částech rostliny Zea mays použitím dvouenergiové rentgenového mikroradiografie a AAS
English title
Detection of lead in Zea mays by dual-energy X-ray microtomography at the SYRMEP beamline of the ELETTRA synchrotron and by atomic absorption spectroscopy
Type
journal article - other
Language
en
Original abstract
This study is related to the application of the X-ray dual-energy microradiography technique together with the atomic absorption spectroscopy (AAS) for the detection of lead on Zea mays stem, ear, root, and leaf samples. To highlight the places with lead intake, the planar radiographs taken with monochromatic X-ray radiation in absorption regime with photon energy below and above the absorption edge of a given chemical element, respectively, are analyzed and processed. To recognize the biological structures involved in the intake, the dual-energy images with the lead signal have been compared with the optical images of the same Z. mays stem. The ear, stem, root, and leaf samples have also been analyzed with the AAS technique to measure the exact amount of the hyperaccumulated lead. The AAS measurement revealed that the highest intake occurred in the roots while the lowest in the maize ears and in the leaf. It seems there is a particular mechanism that protects the seeds and the leaves in the intake process.
Czech abstract
Článek pojednává o detekci rozložení olova v částech rostliny Zea mays použitím dvouenergiové rentgenového mikroradiografie a AAS. Mikroradiografie a mikrotomografie byla zrealizována na synchrotronu Elettra v Terstu. Bylo dosazeno rozliseni kolem 10 um.
English abstract
This study is related to the application of the X-ray dual-energy microradiography technique together with the atomic absorption spectroscopy (AAS) for the detection of lead on Zea mays stem, ear, root, and leaf samples. To highlight the places with lead intake, the planar radiographs taken with monochromatic X-ray radiation in absorption regime with photon energy below and above the absorption edge of a given chemical element, respectively, are analyzed and processed. To recognize the biological structures involved in the intake, the dual-energy images with the lead signal have been compared with the optical images of the same Z. mays stem. The ear, stem, root, and leaf samples have also been analyzed with the AAS technique to measure the exact amount of the hyperaccumulated lead. The AAS measurement revealed that the highest intake occurred in the roots while the lowest in the maize ears and in the leaf. It seems there is a particular mechanism that protects the seeds and the leaves in the intake process.
Keywords in English
dual-energy X-ray analysis, intake, biodisposable, Zea mays, stem, lead
RIV year
2009
Released
01.12.2009
ISSN
1059-910X
Journal
Microscopy research and technique
Volume
XXX
Number
X
Pages from–to
na–na
Pages count
12
BIBTEX
@article{BUT49111,
author="Jozef {Kaiser} and Radomír {Malina} and Miroslav {Liška},
title="Detection of lead in Zea mays by dual-energy X-ray microtomography at the SYRMEP beamline of the ELETTRA synchrotron and by atomic absorption spectroscopy",
journal="Microscopy research and technique",
year="2009",
volume="XXX",
number="X",
month="December",
pages="na--na",
issn="1059-910X"
}