Detail publikace

Detekce rozložení olova v různých částech rostliny Zea mays použitím dvouenergiové rentgenového mikroradiografie a AAS

REALE, L. -KAISER, J. -PACE, L. -LAI, A. -FLORA, F. -BRUNO, A. -TUCCI, A. -ZUPPELLA, P. -MANCINI, L. -TROMBA, G. -RUGGIERI, F. -FANELLI, M. -MALINA, R. -LIŠKA, M. -POMA, A.

Český název

Detekce rozložení olova v různých částech rostliny Zea mays použitím dvouenergiové rentgenového mikroradiografie a AAS

Anglický název

Detection of lead in Zea mays by dual-energy X-ray microtomography at the SYRMEP beamline of the ELETTRA synchrotron and by atomic absorption spectroscopy

Typ

článek v časopise - ostatní, Jost

Jazyk

en

Originální abstrakt

This study is related to the application of the X-ray dual-energy microradiography technique together with the atomic absorption spectroscopy (AAS) for the detection of lead on Zea mays stem, ear, root, and leaf samples. To highlight the places with lead intake, the planar radiographs taken with monochromatic X-ray radiation in absorption regime with photon energy below and above the absorption edge of a given chemical element, respectively, are analyzed and processed. To recognize the biological structures involved in the intake, the dual-energy images with the lead signal have been compared with the optical images of the same Z. mays stem. The ear, stem, root, and leaf samples have also been analyzed with the AAS technique to measure the exact amount of the hyperaccumulated lead. The AAS measurement revealed that the highest intake occurred in the roots while the lowest in the maize ears and in the leaf. It seems there is a particular mechanism that protects the seeds and the leaves in the intake process.

Český abstrakt

Článek pojednává o detekci rozložení olova v částech rostliny Zea mays použitím dvouenergiové rentgenového mikroradiografie a AAS. Mikroradiografie a mikrotomografie byla zrealizována na synchrotronu Elettra v Terstu. Bylo dosazeno rozliseni kolem 10 um.

Anglický abstrakt

This study is related to the application of the X-ray dual-energy microradiography technique together with the atomic absorption spectroscopy (AAS) for the detection of lead on Zea mays stem, ear, root, and leaf samples. To highlight the places with lead intake, the planar radiographs taken with monochromatic X-ray radiation in absorption regime with photon energy below and above the absorption edge of a given chemical element, respectively, are analyzed and processed. To recognize the biological structures involved in the intake, the dual-energy images with the lead signal have been compared with the optical images of the same Z. mays stem. The ear, stem, root, and leaf samples have also been analyzed with the AAS technique to measure the exact amount of the hyperaccumulated lead. The AAS measurement revealed that the highest intake occurred in the roots while the lowest in the maize ears and in the leaf. It seems there is a particular mechanism that protects the seeds and the leaves in the intake process.

Klíčová slova anglicky

dual-energy X-ray analysis, intake, biodisposable, Zea mays, stem, lead

Rok RIV

2009

Vydáno

01.12.2009

ISSN

1059-910X

Časopis

Microscopy research and technique

Ročník

XXX

Číslo

X

Strany od–do

na–na

Počet stran

12

BIBTEX


@article{BUT49111,
  author="Jozef {Kaiser} and Radomír {Malina} and Miroslav {Liška},
  title="Detection of lead in Zea mays by dual-energy X-ray microtomography at the SYRMEP beamline of the ELETTRA synchrotron and by atomic absorption spectroscopy",
  journal="Microscopy research and technique",
  year="2009",
  volume="XXX",
  number="X",
  month="December",
  pages="na--na",
  issn="1059-910X"
}