Detail publikace

Korelace součinitele přestupu tepla na skrápěném trubkovém svazku

KRACÍK, P. ŠNAJDÁREK, L. LISÝ, M. BALÁŠ, M. POSPÍŠIL, J.

Český název

Korelace součinitele přestupu tepla na skrápěném trubkovém svazku

Anglický název

Correlation of Heat Transfer Coefficient at Sprinkled Tube Bundle

Typ

článek v časopise ve Web of Science, Jimp

Jazyk

en

Originální abstrakt

The paper presents a research on the heat-transfer coefficient at the surface of a sprinkled tube bundle, using a boiling simulation. A tube bundle consists of thirteen copper tubes divided into two rows and it is located in a low-pressure chamber where vacuum is generated by an exhauster via an ejector. The liquid tested was water at the absolute pressure in the chamber of 96.8–12.3 kPa and at a thermal gradient of 55–30 °C between the cooled liquid flowing upwards inside the exchanger and the heated falling film liquid. The flow of the falling film liquid ranged from 0–17 L/min. Two types of tubes were tested, a smooth one and a sandblasted one. The correlation of the average heat-transfer coefficient at the surfaces of both tube types was identified.

Český abstrakt

Příspěvek prezentuje výzkum koeficientu přestupu tepla na povrchu skrápěného trubkového svazku na kterém kapalina vře. Svazek se skládá z třinácti měděných trubek rozdělených do dvou řad, a nachází se v nízkotlaké komoře, kde je podtlak vytvořené pomocí ejektoru napojeného na vývěvu. Tekutina byla testována při absolutním tlaku v komoře mezi 96,8 kPa až do 12,3 kPa a tepelného gradientu 55 až 30 ° C mezi chlazenou kapalinou proudící uvnitř výměníku ze spodu vzhůru a klesající vrstvou ohřívané kapaliny. Tok klesající vrstvou kapaliny v rozmezí od nuly do 1 / min. Byly testovány dva typy trubek, hladký a pískovaný. Na závěr byla vytvořena funkční závislost průměrného součinitele přestupu tepla na povrchu obou typů zkoumaných svazků.

Anglický abstrakt

The paper presents a research on the heat-transfer coefficient at the surface of a sprinkled tube bundle, using a boiling simulation. A tube bundle consists of thirteen copper tubes divided into two rows and it is located in a low-pressure chamber where vacuum is generated by an exhauster via an ejector. The liquid tested was water at the absolute pressure in the chamber of 96.8–12.3 kPa and at a thermal gradient of 55–30 °C between the cooled liquid flowing upwards inside the exchanger and the heated falling film liquid. The flow of the falling film liquid ranged from 0–17 L/min. Two types of tubes were tested, a smooth one and a sandblasted one. The correlation of the average heat-transfer coefficient at the surfaces of both tube types was identified.

Klíčová slova česky

skrápění, voda, podtlak, přenos tepla

Klíčová slova anglicky

sprinkled, water, under pressure, heat transfer

Vydáno

12.08.2016

Nakladatel

Inštitut za kovinske materiale in technologije Ljubljana

Místo

Ljubljana

ISSN

1580-2949

Ročník

50

Číslo

4

Strany od–do

479–483

Počet stran

5

BIBTEX


@article{BUT119542,
  author="Petr {Kracík} and Ladislav {Šnajdárek} and Martin {Lisý} and Marek {Baláš} and Jiří {Pospíšil},
  title="Correlation of Heat Transfer Coefficient at Sprinkled Tube Bundle",
  year="2016",
  volume="50",
  number="4",
  month="August",
  pages="479--483",
  publisher="Inštitut za kovinske materiale in technologije Ljubljana",
  address="Ljubljana",
  issn="1580-2949"
}