ŠLECHTOVÁ, M. KOČIŠ, J. Florian, Z. Návrat, T.

Český název

Výpočtové a experimetnální modelování páteřního prvku s aplikovaným fixátorem

Anglický název

Computational and experiemtal modelling of the backbone element with applied fixator

Typ

článek ve sborníku ve WoS nebo Scopus

Jazyk

en

Originální abstrakt

A stress-strain analysis and Experimental study of a spinal element with applied cervical fixator is presented. The problem is solved by the finite element method using commercial software package Ansys 5.7 and 6.1. The present state of elaboration as well as some interesting remarks for the future research in this area are highlighted in conclusion. Established experimental study is performed on 8 vertebra segments with applied fixators Cervi-Lok and Morscher which are suitable for stabilization of cervical spine. Experiments are performend on testing machine called Zwick Z 020 TDN. Combination of loading – tension+torsion and compresion+torsion is applied. In conclusion the assessment of fixator is performed from the view of applied loading

Český abstrakt

Práce se zabývá experimentálním a výpočtovým modelováním páteřního prvku aplikovaným fixátorem. Deformačně-napjatostní analýza je řešena výpočtovým modelováním metodou konečných prvku. Dílčí výpočty jsou řešeny pomocí výpočtového systemu ANSYS. V závěru příspěvku je zhodnocen současný stav rozpracování a naznačen další postup prací. Publikovaná experimentální studie je prováděna na 2 vzorcích krční páteře. Experimenty jsou prováděny na experimentálním stroji Zwick Z 020-TDN, aplikováno je kombinované namáhání tah+krut a tlak+krut. V závěru je provedeno hodnocení implantátů z hlediska aplikovaného namáhání

Anglický abstrakt

A stress-strain analysis and Experimental study of a spinal element with applied cervical fixator is presented. The problem is solved by the finite element method using commercial software package Ansys 5.7 and 6.1. The present state of elaboration as well as some interesting remarks for the future research in this area are highlighted in conclusion. Established experimental study is performed on 8 vertebra segments with applied fixators Cervi-Lok and Morscher which are suitable for stabilization of cervical spine. Experiments are performend on testing machine called Zwick Z 020 TDN. Combination of loading – tension+torsion and compresion+torsion is applied. In conclusion the assessment of fixator is performed from the view of applied loading

Klíčová slova anglicky

biomechanics, cervical spine, fixator, computational modelling, experimental modelling, FEM

Rok RIV

2004

Vydáno

08.09.2004

Nakladatel

Slovak University if Technology in Bratislava

Místo

Bratislava

ISBN

80-227-2105-0

Kniha

Mechanical Engineering 2004

Počet stran

1

BIBTEX


@inproceedings{BUT14298,
  author="Marcela {Šlechtová} and Ján {Kočiš} and Zdeněk {Florian} and Tomáš {Návrat},
  title="Computational and experiemtal modelling of the backbone element with applied fixator",
  booktitle="Mechanical Engineering 2004",
  year="2004",
  month="September",
  publisher="Slovak University if Technology in Bratislava",
  address="Bratislava",
  isbn="80-227-2105-0"
}