Detail publikace

Transient response of magnetorheological fluid on rapid change of magnetic field in shear mode

KUBÍK, M. VÁLEK, J. ŽÁČEK, J. JENIŠ, F. BORIN, D. STRECKER, Z. MAZŮREK, I.

Anglický název

Transient response of magnetorheological fluid on rapid change of magnetic field in shear mode

Typ

článek v časopise ve Web of Science, Jimp

Jazyk

en

Originální abstrakt

The transient behaviour of magnetorheological (MR) devices is an important parameter for modern semi-actively controlled suspension systems. A significant part of the MR device response time is the MR fluid response time itself. A significant factor is the so-called rheological response time. The rheological response time is connected with the structuring particle's time and the development of shear stress in MR fluid during the deformation. The main aim of this paper is to experimentally determine the rheological response time of MR fluid and evaluated the effect of shear rate, magnetic field level, and carrier fluid viscosity. The unique design of the rheometer, which allows the rapid change of a magnetic field, is presented. The rheological response time of MRF 132-DG and MRC-C1L is in the range of 0.8-1.4 ms, depending on the shear rate. The higher the shear rate, the shorter the response time. It can be stated that the higher the magnetization of the MR fluid, the lower the response time. The higher the viscosity, the higher the rheological response time. The measured data of rheological response time was generalized and one master curve was determined.

Anglický abstrakt

The transient behaviour of magnetorheological (MR) devices is an important parameter for modern semi-actively controlled suspension systems. A significant part of the MR device response time is the MR fluid response time itself. A significant factor is the so-called rheological response time. The rheological response time is connected with the structuring particle's time and the development of shear stress in MR fluid during the deformation. The main aim of this paper is to experimentally determine the rheological response time of MR fluid and evaluated the effect of shear rate, magnetic field level, and carrier fluid viscosity. The unique design of the rheometer, which allows the rapid change of a magnetic field, is presented. The rheological response time of MRF 132-DG and MRC-C1L is in the range of 0.8-1.4 ms, depending on the shear rate. The higher the shear rate, the shorter the response time. It can be stated that the higher the magnetization of the MR fluid, the lower the response time. The higher the viscosity, the higher the rheological response time. The measured data of rheological response time was generalized and one master curve was determined.

Klíčová slova anglicky

Time; Bingham

Vydáno

09.07.2022

Nakladatel

Springer Nature

ISSN

2045-2322

Ročník

12

Číslo

1

Strany od–do

1–10

Počet stran

10

BIBTEX


@article{BUT178515,
  author="Michal {Kubík} and Josef {Válek} and Jiří {Žáček} and Filip {Jeniš} and Zbyněk {Strecker} and Ivan {Mazůrek},
  title="Transient response of magnetorheological fluid on rapid change of magnetic field in shear mode",
  year="2022",
  volume="12",
  number="1",
  month="July",
  pages="1--10",
  publisher="Springer Nature",
  issn="2045-2322"
}