Originální abstrakt
Magnetorheological (MR) fluid is a suspension of ferromagnetic micro-size particles in a carrier fluid. MR fluids can operate in four working modes: valve, shear, squeeze and gradient pinch. MR fluid is usually exposed almost homogeneous magnetic field. However, the gradient pinch mode is different because magnetic field distribution is highly non-uniform. This paper aims to present the MR valve measurement working in pinch mode.
Anglický abstrakt
Magnetorheological (MR) fluid is a suspension of ferromagnetic micro-size particles in a carrier fluid. MR fluids can operate in four working modes: valve, shear, squeeze and gradient pinch. MR fluid is usually exposed almost homogeneous magnetic field. However, the gradient pinch mode is different because magnetic field distribution is highly non-uniform. This paper aims to present the MR valve measurement working in pinch mode.
Klíčová slova anglicky
magnetorheological fluid; pinch mode
Vydáno
19.06.2023
Strany od–do
167–167