Detail publikace

Pracovní stanice SYRMEP na synchrotronu Elettra: mamograficke a bio-medikální aplikace

G. Tromba, R. Longo, A. Abrami, F. Arfelli, A. Astolfo, P. Bregant, F. Brun, K. Casarin, V.Chenda, D. Dreossi, M. Hola, J. Kaiser, L. Mancini, R.H. Menk, E. Quai, E. Quaia, L. Rigon, T. Rokvic, N. Sodini, D. Sanabor, E. Schultke, M. Tonutti, A. Vascotto, F. Zanconati, M. Cova, E. Castelli

Český název

Pracovní stanice SYRMEP na synchrotronu Elettra: mamograficke a bio-medikální aplikace

Anglický název

The SYRMEP Beamline of Elettra: Clinical Mammography and Bio-medical Applications

Typ

článek ve sborníku ve WoS nebo Scopus

Jazyk

en

Originální abstrakt

At the SYnchrotron Radiation for MEdical Physics (SYRMEP) beamline of Elettra Synchrotron Light Laboratory in Trieste (Italy), an extensive research program in bio-medical imaging has been developed since 1997. The core program carried out by the SYRMEP collaboration concerns the use of Synchrotron Radiation (SR) for clinical mammography with the aim of improving the diagnostic performance of the conventional technique. The first protocol with patients, started in 2006 has been completed at the end of 2009 and the data analysis is now in progress. Regarding applications different from clinical imaging, synchrotron X-ray computed microtomography (micro-CT) is the most used technique, both in absorption and phase contrast. A new software tool, Pore3D, has been developed to perform a quantitative morphological analysis on the reconstructed slices and to access textural information of the sample under study.

Český abstrakt

Bio-medikální aplikace na pracovní stanici SYRMEP synchrotronu Elettra v Terstu se intenzívně vyvíjejí a zkoumají od roku 1997. Článek pojednává o současném stavu řešené problematiky na dané pracovní stanici a vyjmenuje jednotlivé aplikace.

Anglický abstrakt

At the SYnchrotron Radiation for MEdical Physics (SYRMEP) beamline of Elettra Synchrotron Light Laboratory in Trieste (Italy), an extensive research program in bio-medical imaging has been developed since 1997. The core program carried out by the SYRMEP collaboration concerns the use of Synchrotron Radiation (SR) for clinical mammography with the aim of improving the diagnostic performance of the conventional technique. The first protocol with patients, started in 2006 has been completed at the end of 2009 and the data analysis is now in progress. Regarding applications different from clinical imaging, synchrotron X-ray computed microtomography (micro-CT) is the most used technique, both in absorption and phase contrast. A new software tool, Pore3D, has been developed to perform a quantitative morphological analysis on the reconstructed slices and to access textural information of the sample under study.

Klíčová slova anglicky

mammography, phase contrast, microtomography, quantitative analysis

Rok RIV

2010

Vydáno

01.07.2010

Nakladatel

Springer

ISBN

978-0-7354-0813-5

Kniha

AIP Conference Proceedings

Strany od–do

18–23

Počet stran

6

BIBTEX


@inproceedings{BUT35643,
  author="Jozef {Kaiser} and Markéta {Holá},
  title="The SYRMEP Beamline of Elettra: Clinical Mammography and Bio-medical Applications",
  booktitle="AIP Conference Proceedings",
  year="2010",
  month="July",
  pages="18--23",
  publisher="Springer",
  isbn="978-0-7354-0813-5"
}